Wire Gauge
Size 12 V wiring for current, run length and voltage drop.
Inputsdrag · tap · type
Fig. 22Conductor cross-sections, to scale
§ How it works
Every wire has resistance. Push current through it and some voltage is lost along the way, turning into heat. In a 12 V system there is not much voltage to spare, so cables are usually sized to limit the drop rather than just to avoid melting.
Resistance of a wire
with resistivity for copper, length in metres and cross-section in mm².
Voltage drop
when current goes out on one wire and back on another, because it travels the run twice. if the return is through the body shell, whose resistance is small by comparison.
Minimum cross-section
Rearranged for the area that keeps the drop within a chosen fraction of system voltage :
The sheet then picks the smallest standard gauge that meets both this area and a current rating for bundled chassis wiring. On short runs the current rating is what decides; on long runs voltage drop takes over.
- American Wire Gauge runs backwards: every 3 steps down doubles the area, every 6 steps doubles the diameter.
- Halving the system voltage for the same power doubles the current and halves the allowable drop, so cable area goes up four-fold. That is why 24 V and 48 V systems use so much less copper.